THE HUB

The Hub/LUXUL/Net Switchers/AMS-2616P

LUXUL, Net Switchers

AMS-2616P

Control
IP
Encoding
ASCII
IP
Telnet port 23
Line ending
CRLF
Login
Required. User admin
More from this makerAMS-1208PAMS-4424P

Commands

14 commands
OTHER13
PORT STATUS show interface GigabitEthernet 1/%o status
Reply: 1/%oVariables: %o = switch port numberEnding: crlf
POE STATUS show poe
Reply: PortVariables: PoE power allocation summaryEnding: crlf
IP CONFIGURATION show ip interface brief
Reply: VLANVariables: IPv4 interface summaryEnding: crlf
VLAN STATUS show vlan
Reply: VLAN NameVariables: VLAN membership tableEnding: crlf
MAC ADDRESS TABLE show mac address-table
Reply: TypeVariables: Dynamic/static MAC tableEnding: crlf
HELP ?
Ending: crlf
DIR dir
Ending: crlf
PORT ENABLE configure terminal && interface GigabitEthernet 1/%o && no shutdown && end
Reply: endVariables: %o = switch port number; multi-step CLI (&&)Ending: crlf
PORT DISABLE configure terminal && interface GigabitEthernet 1/%o && shutdown && end
Reply: endVariables: %o = switch port number; multi-step CLI (&&)Ending: crlf
POE ENABLE configure terminal && interface GigabitEthernet 1/%o && poe && end
Reply: endVariables: %o = switch port number; multi-step CLI (&&)Ending: crlf
POE DISABLE configure terminal && interface GigabitEthernet 1/%o && no poe && end
Reply: endVariables: %o = switch port number; multi-step CLI (&&)Ending: crlf
POE CYCLE configure terminal && interface GigabitEthernet 1/%o && no poe && poe && end
Reply: endVariables: %o = switch port number; multi-step CLI (&&)Ending: crlf
SAVE CONFIG copy running-config startup-config
Reply: Building configurationVariables: Persist running configuration to startup memoryEnding: crlf
MENU1
EXIT exit
Ending: crlf

Cheat sheet

driver.cheatSheet()

What it is

The Luxul AMS-2616P is a 26-port managed gigabit AV switch with 16 PoE+ ports and two SFP uplinks. It is managed via Microsemi WebStaX CLI over Telnet port 23 or SSH.

Specs

Ports: 12 - 8 PoE+ RJ45, 2 RJ45, 2 SFP

PoE: IEEE 802.3af/at on ports 1-8

Uplinks: 2 SFP

Switching Capacity

Management: Web UI on port 80, Telnet on 23, SSH on 22

Setup

First Use: The switch ships requiring a login on every management transport. Set the address and credentials in the web UI on port 80, then add the connection in CTRLbot by IP and port. Pressing Connect asks for the username and password and keeps them in encrypted storage.

VLANs: Configured in the switch's own web UI, which CTRLbot opens one tap from the address on the Connect screen. VLAN configuration needs config mode and multi-line command sequences, which this driver deliberately does not attempt.

PoE: IEEE 802.3af/at on ports 1-8

Control: Read-only. Port up/down, PoE on/off and saving configuration all need `configure terminal` and a nested interface context, which is three lines where the command table models one. They are recorded in Roadmap Future Bucket Feature 9 as a catalogue-wide design question.

Support

Power Cycle: Disconnect power for ten seconds.

Factory Reset: Refer to the Luxul AMS-1208P user guide.

About this driver

driver.source()

Confirm each command on your device before you rely on it. Provided as is, with no warranty. To correct something or ask for it to come down, write to info@ctrlbot.io. Licensed CC BY 4.0: credit CTRLbot and link back when you share it. Product page. Manufacturer site.

Revision
1
Updated
2026-11-18
Catalog date
2026-11-18
License
CC-BY-4.0